Question 1
Free
True/False

 Each type of cable has a prescribed bend radius, which is the radius of the maximum arc into which you can loop a cable without impairing data transmission.

Choose correct answer/s

True

False

Check answer
Question 2
Free
True/False

 The TIA/EIA standard for wall jacks in a work area require that at least one outlet be provided for data and one for voice.

Choose correct answer/s

True

False

Check answer
Question 3
Free
True/False

 The industry standard height for a rack in rack units is 42U.

Choose correct answer/s

True

False

Check answer
Question 4
Free
True/False

 A 66 block is more suitable for data connections than the older 110 block.

Choose correct answer/s

True

False

Check answer
Question 5
Free
True/False

 Fiber-optic cable comes in two types: single-mode fiber (SMF) or multimode fiber (MMF).

Choose correct answer/s

True

False

Check answer
Question 6
True/False

 In a rack setup, a device called a KVM allows multiple consoles to connect to a single device on the rack.

Choose correct answer/s
True
False
To unlock the question
Question 7
True/False

 F5 Networks set the standard for the diagram symbols used to represent routers, switches, firewalls, and other devices.

Choose correct answer/s
True
False
To unlock the question
Question 8
True/False

 The process of designing, implementing, and maintaining an entire network is called the system life cycle.

Choose correct answer/s
True
False
To unlock the question
Question 9
Multiple Choice

 When planning horizontal cabling, what is the maximum allowable distance that can be used?

Choose correct answer/s
A
100 feet
B
300 meters
C
1,000 feet
D
100 meters
To unlock the question
Question 10
Multiple Choice

 In general, how much can a twisted-pair's cable be bent before data transmission may be impeded?

Choose correct answer/s
A
No more than two times the diameter of the cable.
B
No more than four times the diameter of the cable.
C
No more than ten times the diameter of the cable.
D
Twisted pair cable has a near infinite bend radius.
To unlock the question
Question 11
Multiple Choice

 What statement accurately describes what a cable bend radius determines?

Choose correct answer/s
A
A cable bend radius is the radius of the maximum arc into which you can loop the cable without impairing data.
B
A cable bend radius is the radius of the minimum arc into which you can loop the cable without impairing data.
C
A cable bend radius determines the total number of bends that can exist in an overall cable before data is impaired.
D
A cable bend radius defines the twist rate of the cable inside of the insulation.
To unlock the question
Question 12
Multiple Choice

 In order to ensure that a cable is not affected by electromagnetic interference, how far away should the cable be from fluorescent lighting?

Choose correct answer/s
A
at least 3 inches
B
at least 3 feet
C
at least 6 feet
D
at least 12 feet
To unlock the question
Question 13
Multiple Choice

 What is NOT a TIA/EIA recognized cabling type that can be used for horizontal cabling?

Choose correct answer/s
A
RG-6 Coaxial
B
unshielded twisted pair (UTP)
C
shielded twisted pair (STP)
D
fiber-optic
To unlock the question
Question 14
Multiple Choice

 What component of the backbone runs between a building's floors and can be used to connect an MDF and IDF or multiple IDFs?

Choose correct answer/s
A
horizontal cross connect
B
patch cable
C
vertical cross connect
D
diagonal cabling
To unlock the question
Question 15
Multiple Choice

 Where is a demarc located in relation to the structured cabling of an enterprise environment?

Choose correct answer/s
A
in the Main Distribution Frame (MDF)
B
at the Intermediate Distribution Frame (IDF)
C
in the work area
D
between the MDF and the IDF
To unlock the question
Question 16
Multiple Choice

 What component of enterprise level structured cabling serves as the location where an incoming network interface enters a building and connects with the building's backbone cabling?

Choose correct answer/s
A
network interface device
B
main distribution frame
C
intermediate distribution frame
D
entrance facility
To unlock the question
Question 17
Multiple Choice

 During termination of twisted pair cabling, what should be done to ensure minimal cross talk is introduced?

Choose correct answer/s
A
No more than 1 inch of the cable should be exposed.
B
No less than 1 inch of the cable should be exposed.
C
Each pair should be stripped of insulation so that it doesn't get caught in the jack.
D
Each pair should be twisted around another pair to reduce cross talk.
To unlock the question
Question 18
Multiple Choice

 What statement correctly identifies the purpose of a software patch?

Choose correct answer/s
A
A software patch is a correction, improvement, or enhancement to software.
B
A software patch is a major change to a software package that enhances the functionality and features of the software, while also correcting bugs and vulnerabilities.
C
A software patch involves the process of reverting to a previous version of software after attempting to upgrade it.
D
A software patch is a container for new software, and must be installed on relevant devices and incorporated with network resources.
To unlock the question
Question 19
Multiple Choice

 What type of diagram is a graphical representation of a network's wired infrastructure?

Choose correct answer/s
A
network diagram
B
wiring schematic
C
topology map
D
system diagram
To unlock the question
Question 20
Multiple Choice

 Which of the following is a document that is sent as a request to vendors to submit a proposal for a product or service that your company wants to purchase?

Choose correct answer/s
A
memorandum of understanding
B
statement of work
C
request for quote
D
request for proposal
To unlock the question